ELLA 150 IONIZATION CENTRAL HEATING BOILER
ELLA 150 IONIZATION CENTRAL HEATING BOILER (FOR APARTMENTS)
PRICE 1575 €
DETAILS
It is important to know that the power of the ionization heating boiler increases slowly and gradually (yet not in stages) with the increase of the water temperature, from about 2 to 4 kW, thus avoiding the starting shocks characteristic of resistance heating devices.
The electronic unit of our ionization boilers ensures the gradual increase of the power, thus avoiding the overload of the electrical network.
ELLA 150 is recommended for spaces up to 70 sqm or 150 cbm, provided there is a good insulation, primarily of the ceiling (with polystyrene or mineral wool), a shortest route of the pipes without distributors, and there are oversized radiators located on interior walls, not under windows.
Requires much lower installed power than resistance heating boilers, the maximum absorption power of our models being correlated with the standard charging capacity of a Romanian household electrical network. But due to its outstanding performance, its heating power is equivalent to the power of an ordinary 6 kW resistance heating boiler.
The thermal agent is a special antifreeze developed for our heating boilers, which can be diluted with distilled water. The use of any antifreeze or water from wells with increased salinity or hardness is strictly prohibited.
ADVANTAGES: fast installation, very extensive power supply network, no emissions, no air required for combustion, no flue gas chimney, high comfort.
The only ionization central heating boilers that operate with differential fuses, which means that the absorption of current can be limited.
Technical data:
– Seasonal energy efficiency class A+
– 99% seasonal energy efficiency
– Power supply: 220 V
– Rated power output: 4 kW (equivalent to 6-9 kW resistance heating boilers)
– Rated current (intensity): 25 A
– Absorbed electric power: max. 4.5 kW
– Level of protection IP 41
– Digital control panel with instantaneous consumption indicator in kW
– Work pressure: 0 - 1.5 bar;
– Recirculation pump included
– Maximum temperature for the heating circuit: 70°C
– Recommended working temperature: 60°C
– Flow and return connection: 3/4"
– Completely automated, no maintenance is needed
– Frost protection, automatic start at a temperature below 7°C
– Uptime of more than 10 years
– Acoustic power level: 10 dB
– Max. dimensions: 27 x 22 x 61 cm
– Weight: 13 Kg
– The warranty of the heating boiler is 2 years, and for the heating element (electrode) it is 5 years, provided that the instructions for use and installation are strictly observed

